Doubel Combustion Chamber
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.
Read MoreHigh Temperature Incineration
Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Read MoreGet Lastest News
There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation
Read MoreNanjing Clover Medical Technology Co.,Ltd.
Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201
Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.
Latest Post
laboratory incinerator china manufacturer
Incinerator dual chamber with capacity 1.5 m3/batch or 6 m3/ day, digital thermocontrol range 0‐1200
C, thermocouple, air supply capacity 10m3/ minute, power consumption 1.2kWH/ hour, power 3
phase with netral, cooling water sprinkler capacity 5L/ minute, completed with refractory (insulation,
castable, ceramic blanket) and PLC
SUPPLY, INSTALLATION AND COMMISSIONING OF WASTE INCINERATOR – TECHNICAL SPECIFICATIONS
The Waste Incinerator is designed to burn Type IV of pathological waste and infectious, contaminated “red bag,” surgical
dressings, plastic test devices and other wastes.
General Specifications
Burner: 2 burners (primary burner and second burner)
Fuel: Oil
Capacity (Cubic Mtr): 0.65
Ave Capacity: 60 kg per hour
Fuel Consumption (ltrs / hr):13
External Dimensions
Length (mm): 2300
Width (mm): 1220
Height Incl. Flue (mm) 7000
Door Opening (mm) 610 x 710 610 x 710
Operation
Min. Operating Temperature: 950
Max. Operating Temperature: 1320
Residency Time in Second Chamber: 5 sec
Temperature Monitoring: YES
Other clarification
Easy and safe operation
Large counter-balanced fill door with electrical lockout.
Automatic control system provides preset burn times and shut off.
Reload light indicates to operator when it is time to recharge.
Be required for burnout of final charge.
Low energy consumption levels
Programmable digital temperature controls maintain temperature, assuring complete combustion while conserving fuel.
Pressure blower with modulating air control creates turbulence and distributes combustion air to secondary chamber.
Secondary burner with temperature activated modulating control provides fast preheat and sustains high temperature
performance at low energy consumption levels.
Charging rate
incinerator medical waste manufacturer
incinerator type of pyrolytic medical waste incinerator capacity
Including:Incinerator: Structure to be specified
The mark to be specified
Water temperature: 800 to 1000 ° C;
Refractory
Temperature of more than 1100 ° C + obtained;
Capacity: 20-50 kg / hour
Fireplace: 4 to 6 meters high;
Dimension 70 cmx70 crn
Height: 1.10 meters
Fuel: coal;
Aspiration: natural
– A receiving cage for biomedical waste;
– A combustion chamber with a chimney with a filter to retain the ashes;
Chimney section: about 300 cm; With a minimum height of 6 m
Door size: approximately 50×60 cm
Supplied with a 500 liters fuel tank and all necessary accessories for installation.
– INCINERATOR for pharmaceutical waste treatment with a scrubbing system
With the following technical data:
1. One pharma solid waste incinerator unit containing two combustion chambers and based on steel base with scrubbing
system.
2. Working hour /day: minimum 10 hours/day.
3. Capacity: Approximated 150 kg/hr. Over 10 hrs.
4. Wastes characteristics:
· BULK density: 70 – 100 kg/ bm³.
· Calorific value: 2000-3000 kcal / hr.
· Moisture content: 20-30%by weight.
· Ash content: 2 – 8 % by weight.
· Plastic content: 15-20 % by weight.
5. Two combustion chambers.
6. Operating temperatures:
· First chamber: not less than 700 – 800 °c.
· Second chamber: not less than 1200 °c (during steady operation).
7. The burners should be automatically switched off if any of the combustion chambers doors is open.
8. The burners of the first and second combustion chambers are selected for burning diesel oil (light fuel).
9. Automatic loader and unloader to be provided.
10. Exhaust gases to be comply with International Environmental code and requirements.
diesel oil fired medical waste incenerator
High Temperature Waste Incinerator Model D. MB 750XL Burn Rate-150Kg/hour minimum Weight(Kg)-4000kg Secondary Chamber
(double chamber with post-burning) Gas Retention Time 2 second Fuel Diesel Power Supply for control box 220V-240, single
phase 50-60Hz Minimum operating temperature 1200 oC One year spare parts package for complete maintainability 10m hose
pipe. 1100 litre fuel Tank +pipe system Containerised (the container will serve as housing) Additional chimney extension
1 metre high One (1) year warranty.
Incinerator of 20 Kg : 03 Units
Electrically controlled incinerator.
Two-compartment incinerator with a capacity of 20 kg / hour.
Incinerator with low maintenance and operating costs; Equipped with an automatic control panel and easy to use with
electromagnetic locking of the door.
A main waste reduction chamber of 900 ° C. A post secondary combustion chamber of gases generated in the primary chamber
at least 1100 ° C.
Carbon residues in ash less than 5% by weight in accordance with European Directive 2000/76 / EC.
With refractory lining in materials of higher quality
1/ Cost of a 200kgs/Hr medical waste incinerator.
2/ (CIF Term) Cost of shipping from factory to PAPUA NEW GUINEA seaport of LAE, Morobe province
3/ Cost of 2 Clover engineers to Supervise, Installation, Training our engineers and commissioning the medical; waste
incinerator.
manufacturer of ha zardous waste incinerator in china
Burning Capacity: 125 kg minimum/time (3-6times/day), double chamber, double combustion system
Imputing door Mouth Width (mm): 760*760 (approx.)
Chimney External Diameter (mm): 300 ± 10
Combustion Improver Device: 0.11kw, Fuel consumption: 7kg/ hour (max)
Re-Burning Device: Oil consumption: 5kg/h, 0.37kw, Oil consumption: 10-20kg/h
Voltage: 380v/220v AC, Warranty: 1 Year, 50 Hz
Per your advertisement for 300 kg.hr. Model – We need to know the price via return.
How many Kg. of Fuel would be required for running this Model 10 hrs. everyday.
We have our own Freight Forwarding Agent.
We had a Contract for Garbage Management before their Civil War for 120 Tons/Day for one Municipality in North Africa
Medical Waste Incinerator
Dual Chamber (Primary & Secondary) with insulation slabs (fully insulated internal refractory lining) along with
controlled air blower for each chamber
Insulation / Refractory Thickness: ≥ 100mm
Chamber plate thickness: ≥ 6mm
Fuel Type: Natural gas based on burning fuel in combustion chambers
Waste Capacity: ≈ 150 Kg/Day
Incineration capacity: ≈ 25 Kg/Day (Separate waste charging and waste removal doors)
Burners: At least with (02) burners of automated start and stop functions
Combustion efficiency: > 97%
Temperature: programmable temperature with temp monitoring system
Residence time: 2 second in secondary chamber
Heating value: 4000 Kcal
Temperature Range: ≈ min 800ºC to max 1200ºC
Electrical supply: 220V with single phase
Chimney Plate Thickness: ≥ 5mm
Water scrubber: Scrubbing using reagent like lime & should made of SS 10 gauge of non-corrosion properties and painted
exteriorly by equipment grade heat resistive enamel
Chimney Height: between 15-25 feet